Microbiological contamination of composite resins used in a Dental school clinic
DOI:
https://doi.org/10.30979/revabeno.v21i1.1018Keywords:
Containment of Biohazards, Composite Resins, Dental Clinics, Biological Contamination.Abstract
The aim of this study was to verify the microbiological contamination in composite resins used at one Dental school clinic. This is an experimental/laboratory study, in which samples of 10 tubes of composite resin were collected, one of which was the negative control. Portions of composite resin inside the tubes were collected and dipped in test tubes containing nutrient broth for subsequent seeding on to plates and staining for the characterization of bacterial and fungal colonies. All samples revealed contamination, including the tube containing culture medium used as control for handling the experiment. These contaminations may be related to failures in biosafety measures employed in the Dental school clinic and to the transport and storage methods for the tubes of composite resin. Therefore, it is necessary to raise awareness among students and teachers to adopt specific biosafety measures for the handling of composite resins.
Downloads
References
(1) Thomas MV, Jarboe G, Frazer RQ. Infection control in the dental office. Dent Clin North Am. 2008 Jul;52(3):609-28.
(2) Araujo MW, Andreana S. Risk and prevention of transmission of infectious diseases in dentistry. Quintessence Int. 2002 May;33(5):376-82.
(3) World Health Organization [Internet]. USA: World Health Organization; c2020 [cited 2021, Mar 29] WHO Director-General's opening remarks at the media briefing on COVID-19. [Acesso em 29 mar. 2021]. Disponível em: https://www.who.int/director-general/ speeches/detail/who-director-general-s-opening-remarks-at-the-media-briefing-on-covid-19---11-march-2020.
(4) Gamio L. The workers who face the greatest coronavirus risk. The New York Times [Internet]. 2020 mar 15 [Acesso em 29 mar. 2021]. Disponível em: https://www.nytimes.com/interactive/2020/03/15/business/economy/coronavirus-worker-risk.html.
(5) Meng L, Hua F, Bian Z. Coronavirus Disease 2019 (COVID-19): Emerging and future challenges for dental and oral medicine. J Dent Res 2020; 99(9):1113.
(6) Peng X, Xu X, Li Y, Cheng L, Zhou X, Ren B. Transmission routes of 2019-nCoV and controls in dental practice. Int J Oral Sci. 2020; 12(1):9.
(7) Almeida JCF, Prado AKS, Silva WC, Pedrosa SF, Moura MAO, Chaves RM et al. Contaminação de resinas compostas em consultórios odontológicos. ROBRAC. 2010;19(50): 211-5.
(8) Ferraz C, Rocha CG, Rocha MMN, Martins MGA, Jacques P. Contaminação de resinas compostas na prática odontológica. Pesqui Bras Odontoped Clin Integr. 2010; 10(1): 73-8.
(9) Oliveira M, Barreto RM, Salgado IO, Chaves Filho HDM, Diniz CG. Avaliação da contaminação bacteriana em resinas compostas utilizadas nas clínicas de graduação da FO-UFJF. Odontol Clin -Cient. 2010; 9(1): 73- 6.
(10) Lages SMR, Santos AF, Silva Junior FF, Costa JG. Formação em odontologia: O papel das instituições de ensino na prevenção do acidente com exposição a material biológico. Cienc Trab. 2015; 17(54): 182-187.
(11) Cardoso CT, Júnior JRP, Pereira EA, Barros LM, Freitas ABDA. Contaminação de tubos de resina composta manipulados sem barreira de proteção. ROBRAC. 2010; 18(48): 71-75.
(12) Montenegro G, Dornas KV, Melo MES, Saldanha RR. Contaminação da parte externa dos tubos de resina composta. Rev Assoc Paul Cir Dent. 2004;58(4):279-82.
(13) Jorge AOC, Koga-Ito CY, Maegi B, Barbosa APP, Komiyama EY. Desinfecção de superfície em odontologia: avaliação do álcool gel 70 INPM, lenços embebidos em solução de clorexidina e spray de cloreto benzalcônio. RGO (Porto Alegre). 2005; 53(2): 151-4.
(14) Aleixo RQ, Queiroz RC, Custódio VC, Moura JA. Contaminação dos tubos de resina composta utilizados na clínica odontológica. ClipeOdonto-UNITAU. 2010; 2(1): 39-45.
(15) Andrade ICGB, Silva Filho HH, Zimath T, Galiassi CD. Avaliação da contaminação microbiológica em resinas compostas utilizadas nas clínicas odontológicas da Universidade Regional de Blumenau. RFO UPF 2018; 22(3):281-7.
(16) Yamaji A, Koga K, Tsujimoto A, Shimizu Y, Tsubota K, Takamizawa T, Miyazaki, M. Influence of oxygen-inhibited layer on dentin bond strength of chemical-cured resin composite. European Journal of Oral Sciences 2013; 121(5), 497-503.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Revista da ABENO
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Autores que publicam nesta revista concordam com os seguintes termos:
a) Autores mantém os direitos autorais e concedem à revista o direito de primeira publicação, com o trabalho simultaneamente licenciado sob a Licença Creative Commons Attribution que permite o compartilhamento do trabalho com reconhecimento da autoria e publicação inicial nesta revista.
b) Autores têm autorização para assumir contratos adicionais separadamente, para distribuição não-exclusiva da versão do trabalho publicada nesta revista (ex.: publicar em repositório institucional ou como capítulo de livro), com reconhecimento de autoria e publicação inicial nesta revista.
c) Autores têm permissão e são estimulados a publicar e distribuir seu trabalho online (ex.: em repositórios institucionais ou na sua página pessoal) a qualquer ponto antes ou durante o processo editorial, já que isso pode gerar alterações produtivas, bem como aumentar o impacto e a citação do trabalho publicado (Veja O Efeito do Acesso Livre).